{"id":2049,"date":"2023-05-28T10:04:35","date_gmt":"2023-05-28T02:04:35","guid":{"rendered":"http:\/\/wp.wdeerelec.com\/?post_type=product&#038;p=2049"},"modified":"2026-11-14T22:43:40","modified_gmt":"2026-11-14T14:43:40","slug":"%e5%98%89%e7%81%b5carling-n%e7%b3%bb%e5%88%97%e6%b6%b2%e5%8e%8b%e7%94%b5%e7%a3%81%e6%96%ad%e8%b7%af%e5%99%a8","status":"publish","type":"product","link":"https:\/\/www.wdeerelec.com\/index.php\/product\/%e5%98%89%e7%81%b5carling-n%e7%b3%bb%e5%88%97%e6%b6%b2%e5%8e%8b%e7%94%b5%e7%a3%81%e6%96%ad%e8%b7%af%e5%99%a8\/","title":{"rendered":"\u5609\u7075Carling N\u7cfb\u5217\u6db2\u538b\u7535\u78c1\u65ad\u8def\u5668"},"content":{"rendered":"<p><strong>Carling N-Series<\/strong>\uff08N\u7cfb\u5217\u6db2\u538b\u7535\u78c1\u65ad\u8def\u5668\uff09<\/p>\n<h3>\u4ea7\u54c1\u6982\u8ff0<\/h3>\n<p>\u672c\u9875\u4e3a Carling Technologies\uff08Littelfuse \u65d7\u4e0b Littelfuse \u54c1\u724c\u4f53\u7cfb\uff09N\u7cfb\u5217\u6db2\u538b\u7535\u78c1\u65ad\u8def\u5668\u7cfb\u5217\u8d44\u6599\uff0c\u5185\u5bb9\u6574\u7406\u81ea\u5b98\u65b9\u7cfb\u5217\u9875\uff0c\u53c2\u6570\u4e0e\u53ef\u9009\u578b\u53f7\u4ee5\u5b98\u65b9\u6700\u65b0\u53d1\u5e03\u4e3a\u51c6\u3002\u6838\u5fc3\u6307\u6807\uff1aClick to see full view\uff1b\u989d\u5b9a\u7535\u6d41 Maximum 30 amps; 20 amps for single pole\uff1b\u989d\u5b9a\u7535\u538b Maximum 120\/240VAC; up to 240VAC for single pole\uff1bMaximum Interrupting Capacity 22,000 amps; 10,000 amps for single pole\u3002<\/p>\n<p>Specifically engineered for the shrinking space requirements found in today\u2019s electronic equipment, particularly power distribution units and rack systems, the full-featured N-Series offers an innovative low profile design, as well as several value-add features ideal for datacom and telecom industries. These features include line and load terminals at the top and bottom of the casing for easier installation in tight spaces, as well as an optional current transformer, capable of sensing current down to 1%. This optional feature allows for remote outlet metering of power usage to facilitate more accurate and efficient billing.<\/p>\n<p>The N-Series then adds UL 489 compliant sliding terminal barriers that seamlessly glide into place and a patented flush rocker actuator with push-to-reset guard to protect against inadvertent actuation.<\/p>\n<p>This up to 30 amp breaker is configurable in one or two poles.<\/p>\n<h3>\u4ea7\u54c1\u7279\u70b9<\/h3>\n<ul>\n<li>\u989d\u5b9a\u7535\u6d41\uff08Amperage\uff09\uff1aMaximum 30 amps; 20 amps for single pole<\/li>\n<li>\u989d\u5b9a\u7535\u538b\uff08Voltage\uff09\uff1aMaximum 120\/240VAC; up to 240VAC for single pole<\/li>\n<li>Maximum Interrupting Capacity\uff08Maximum Interrupting Capacity\uff09\uff1a22,000 amps; 10,000 amps for single pole<\/li>\n<li>\u8ba4\u8bc1\uff08Agency Approvals\uff09\uff1aUL 489, TUV certified to IEC\/EN 60947-2<\/li>\n<\/ul>\n<h3>\u89c4\u683c\u53c2\u6570<\/h3>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\">\n<tr style=\"background-color:#f5f5f5;font-weight:bold;\">\n<td style=\"width:40%;\">\u53c2\u6570\u9879<\/td>\n<td>\u89c4\u683c<\/td>\n<\/tr>\n<tr>\n<td>\u6781\u6570\uff08Number of Poles\uff09<\/td>\n<td>1-2 Poles<\/td>\n<\/tr>\n<tr>\n<td>Maximum Current and Voltage Ratings\uff08Maximum Current and Voltage Ratings\uff09<\/td>\n<td>1-30A @ 120\/240VAC<\/td>\n<\/tr>\n<tr>\n<td>1-20A @ 240VAC\uff081-20A @ 240VAC\uff09<\/td>\n<td>Auxiliary Swich Ratings<\/td>\n<\/tr>\n<tr>\n<td>N\/A\uff08N\/A\uff09<\/td>\n<td>Available Circuits<\/td>\n<\/tr>\n<tr>\n<td>Series Trip\uff08Series Trip\uff09<\/td>\n<td>Current Metering<\/td>\n<\/tr>\n<tr>\n<td>Available with or without integrated current transformer\uff08Available with or without integrated current transformer\uff09<\/td>\n<td>Actuator Style<\/td>\n<\/tr>\n<tr>\n<td>Flush Rocker\uff08Flush Rocker\uff09<\/td>\n<td>Flush Rocker with Push-to-Reset Guard<\/td>\n<\/tr>\n<tr>\n<td>\u7aef\u5b50\u9009\u9879\uff08Terminal Options\uff09<\/td>\n<td>Screw Terminal with sliding terminal barriers<\/td>\n<\/tr>\n<tr>\n<td>\u5b89\u88c5\u65b9\u5f0f\uff08Mounting Method\uff09<\/td>\n<td>Front Panel<\/td>\n<\/tr>\n<tr>\n<td>Value Added\uff08Value Added\uff09<\/td>\n<td>Optional Current Monitor<\/td>\n<\/tr>\n<tr>\n<td>Custom actuator colors\uff08Custom actuator colors\uff09<\/td>\n<td>Non-standard amp ratings<\/td>\n<\/tr>\n<\/table>\n<h3>\u5e94\u7528\u9886\u57df<\/h3>\n<ul>\n<li>Datacom\/Telecom:<\/li>\n<li>Power Distribution Units<\/li>\n<li>Data Servers<\/li>\n<li>Data Storage<\/li>\n<\/ul>\n<p style=\"margin-top:24px;color:#888;font-size:13px;\">\u8d44\u6599\u6765\u6e90\uff1a<a href=\"https:\/\/www.carlingtech.com\/hm-cb-n-series\" target=\"_blank\" rel=\"nofollow\">https:\/\/www.carlingtech.com\/hm-cb-n-series<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4e13\u4e3a\u5f53\u4eca\u7535\u5b50\u8bbe\u5907\uff0c\u7279\u522b\u662f\u914d\u7535\u5355\u5143\u548c\u673a\u67b6\u7cfb\u7edf\u4e2d\u4e0d\u65ad\u7f29\u5c0f\u7684\u7a7a\u95f4\u9700\u6c42\u800c\u8bbe\u8ba1\u7684\u5168\u529f\u80fdN\u7cfb\u5217\uff0c\u5177\u6709\u521b\u65b0\u7684\u4f4e\u5916\u5f62\u8bbe\u8ba1\uff0c\u4ee5\u53ca\u4e00\u4e9b\u975e\u5e38\u9002\u5408\u6570\u636e\u901a\u4fe1\u548c\u7535\u4fe1\u884c\u4e1a\u7684\u589e\u503c\u529f\u80fd\u3002\u8fd9\u4e9b\u529f\u80fd\u5305\u62ec\u5957\u7ba1\u9876\u90e8\u548c\u5e95\u90e8\u7684\u7ebf\u8def\u548c\u8d1f\u8f7d\u7aef\u5b50\uff0c\u4ee5\u4fbf\u4e8e\u5728\u72ed\u7a84\u7684\u7a7a\u95f4\u5b89\u88c5\uff0c\u4ee5\u53ca\u53ef\u9009\u7684\u7535\u6d41\u4e92\u611f\u5668\uff0c\u80fd\u591f\u611f\u5e94\u5230\u4f4e\u4e8e1%\u7684\u7535\u6d41\u3002\u8fd9\u4e00\u53ef\u9009\u529f\u80fd\u53ef\u4ee5\u8fdc\u7a0b\u63d2\u5ea7\u8ba1\u91cf\u7535\u529b\u4f7f\u7528\uff0c\u4ee5\u4fbf\u4e8e\u66f4\u51c6\u786e\u548c\u6709\u6548\u5730\u8ba1\u8d39\u3002N\u7cfb\u5217\u8fd8\u6dfb\u52a0\u4e86\u7b26\u5408UL 489\u6807\u51c6\u7684\u6ed1\u52a8\u7ec8\u7aef\u5c4f\u969c\uff0c\u53ef\u4ee5\u65e0\u7f1d\u5730\u6ed1\u52a8\u5230\u4f4d\uff0c\u4e13\u5229\u7684\u9690\u85cf\u5f0f\u8df7\u677f\u81f4\u52a8\u5668\uff0c\u81f4\u52a8\u5668\u5177\u6709\u6309\u4e0b\u590d\u4f4d\u4fdd\u62a4\uff0c\u4ee5\u9632\u6b62\u610f\u5916\u542f\u52a8\u3002  \u65ad\u8def\u5668\u6700\u5927\u7535\u6d4130\u5b89\u57f9\uff0c\u53ef\u914d\u7f6e1-3\u6781\u3002<\/p>\n","protected":false},"featured_media":13414,"template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_brand":[281],"product_cat":[102,16],"product_tag":[34],"class_list":["post-2049","product","type-product","status-publish","has-post-thumbnail","product_brand-carling","product_cat-hydraulic-magnetic-circuit-breaker","product_cat-breaker","product_tag-carling","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product\/2049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/media\/13414"}],"wp:attachment":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/media?parent=2049"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=2049"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=2049"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=2049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}