{"id":3808,"date":"2023-06-07T15:44:03","date_gmt":"2023-06-07T07:44:03","guid":{"rendered":"http:\/\/wp.wdeerelec.com\/?post_type=product&#038;p=3808"},"modified":"2023-06-07T15:46:41","modified_gmt":"2023-06-07T07:46:41","slug":"%e5%ae%89%e8%b4%b9%e8%af%baamphenol-i2s-%e6%b0%a2%e6%b0%94%ef%bc%88h2%ef%bc%89%e5%8e%8b%e5%8a%9b%e4%bc%a0%e6%84%9f%e5%99%a8-lps%ef%bc%8cmps%ef%bc%8chps-%e7%94%a8%e4%ba%8e%e6%b0%a2%e6%b0%94","status":"publish","type":"product","link":"https:\/\/www.wdeerelec.com\/index.php\/product\/%e5%ae%89%e8%b4%b9%e8%af%baamphenol-i2s-%e6%b0%a2%e6%b0%94%ef%bc%88h2%ef%bc%89%e5%8e%8b%e5%8a%9b%e4%bc%a0%e6%84%9f%e5%99%a8-lps%ef%bc%8cmps%ef%bc%8chps-%e7%94%a8%e4%ba%8e%e6%b0%a2%e6%b0%94\/","title":{"rendered":"\u5b89\u8d39\u8bfaAmphenol i2s \u6c22\u6c14\uff08H2\uff09\u538b\u529b\u4f20\u611f\u5668 &#8211; LPS\uff0cMPS\uff0cHPS &#8211; \u7528\u4e8e\u6c22\u6c14\u7cfb\u7edf\u548c\u50a8\u7f50"},"content":{"rendered":"<p>\u538b\u529b\u4f20\u611f\u5668LPS\uff0cMPS\u548cHPS\u662f\u4e13\u4e3a\u6c22\u5e94\u7528\uff08H2\uff09\u4f7f\u7528\u800c\u8bbe\u8ba1\u7684\uff0c\u4f8b\u5982\u71c3\u6599\u7535\u6c60\uff0c\u52a0\u6cb9\u7ad9\u548c\u9ad8\u538b\u7f50\u3002\u8be5\u4ea7\u54c1\u7cfb\u5217\u5305\u62ec\u4e09\u4e2a\u7248\u672c\uff0c\u53ef\u6d4b\u91cf\u9ad8\u8fbe6bar\uff08LPS\uff09\u548c30bar\uff08MPS\uff09\u7684\u538b\u529b\u4ee5\u53ca\u9ad8\u8fbe900bar\uff08HPS\uff09\u7684\u9ad8\u538b\u3002<\/p>\n<p>\u9002\u7528\u573a\u5408<br \/>\n.H2\u7684\u751f\u4ea7\u3001\u4f7f\u7528\u548c\u50a8\u5b58\u7cfb\u7edf<br \/>\n.\u5de5\u4e1a\u548c\u6c7d\u8f66\u5e94\u7528<br \/>\n.\u71c3\u6599\u7535\u6c60<br \/>\n.\u9ad8\u538b\u7f50\uff0c\u50a8\u5b58\u548c\u52a0\u6ce8\u7ad9\uff0c\u6c22\u6c14\u52a0\u6ce8\u7ad9<br \/>\n.\u6d4b\u91cf\u548c\u6d4b\u8bd5\u6280\u672f\u5e94\u7528<br \/>\n\u4ea7\u54c1\u7279\u6027<br \/>\nKEY FEATURES BENEFITS<br \/>\nHydrogen pressure measurement up to 900 bar \u00b7 Robust for pressure ranges up to 900 bar<br \/>\n\u00b7 Mono-part sensing element without welded parts<br \/>\nHigh level of hydrogen compatibility \u00b7 Use of media-tested materials<br \/>\n\u00b7 Burst proof and high durability<br \/>\n\u00b7 Freezing robust design<br \/>\n\u00b7 Certified according to EC79 and HGV 3.1<br \/>\nNumerous design versions available \u00b7 Analog output voltage and SENT and LIN output<br \/>\n\u00b7 Different mechanical connectors available (metric and UNF)<br \/>\n\u00b7 High pressure sensor with cone seal<br \/>\nMeasurement range<br \/>\nNominal pressure 0\u20266 bar, absolute 1) (LPS)<br \/>\n0\u202630 bar, relative 1) (MPS)<br \/>\n0\u2026900 bar, relative 1) (HPS)<br \/>\nOverpressure 2x nominal pressure (LPS,MPS), 1,050 bar (HPS)<br \/>\nBursting pressure 3x nominal pressure (LPS,MPS), 1,750 bar (HPS)<br \/>\nElectrical characteristics<br \/>\nSupply voltage 5 \u00b1 0.5 V (analog, SENT)<br \/>\n9\u202618 V (LIN)<br \/>\nSupply current \u00a0typ. 10 mA<br \/>\nOutput signal 0.5\u20264.5 V, ratiometric<br \/>\nSENT<br \/>\nLIN 2.1<br \/>\nOvervoltage protection \u00b1 30 V<br \/>\nReverse polarity protection 2) \u00b1 30 V<br \/>\nAccuracy<br \/>\nTotal error(Standard version) \u00b1 1% FS (0\u202685\u00b0C)<br \/>\n\u00b1 2% FS (-40\u2026125\u00b0C)<br \/>\nTotal error(High-precision version) \u00b1 0.5% FS<br \/>\nEnvironmental conditions<br \/>\nOperating temperature range -40\u202685\u00b0C (125\u00b0C)<br \/>\nMedia temperature range -50\u202685\u00b0C (125\u00b0C)<br \/>\nMedia compatibility<br \/>\nHydrogen, air, coolant<br \/>\n(DI-water, ethylene glycol)<br \/>\nESD (DIN EN 61000-4-2) 2)<br \/>\n\u00b1 8 kV to contacts<br \/>\n\u00b1 15 kV to case<br \/>\nEMV (ISO 11452) 2) 250 V\/m<br \/>\n200 mA (BCI)<\/p>\n<p>\u6c7d\u8f66\u5e94\u7528:\u6c22\u80fd\u6e90\u6c22\u6c14\u538b\u529b\u6d4b\u91cf<br \/>\n\u538b\u529b\u7279\u6027:\u9ad8\u538b\uff1b\u4e2d\u538b<br \/>\n\u4fe1\u53f7\u68c0\u6d4b:\u538b\u529b<br \/>\nEV\/HEV:\u6c22\u80fd\u6e90\u6c22\u6c14\u538b\u529b\u6d4b\u91cf<br \/>\n\u5de5\u4e1a\u5e94\u7528:\u6c22\u6c14\u53ca\u6c22\u6c14\u7f50\u538b\u529b\u6d4b\u91cf<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u538b\u529b\u4f20\u611f\u5668LPS\uff0cMPS\u548cHPS\u662f\u4e13\u4e3a\u6c22\u5e94\u7528\uff08H2\uff09\u4f7f\u7528\u800c\u8bbe\u8ba1\u7684\uff0c\u4f8b\u5982\u71c3\u6599\u7535\u6c60\uff0c\u52a0\u6cb9\u7ad9\u548c\u9ad8\u538b\u7f50\u3002<\/p>\n","protected":false},"featured_media":3810,"template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[23,53],"product_tag":[35],"class_list":["post-3808","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-sensor","product_cat-pressure-sensors","product_tag-amphenol-sensors","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v3\/product\/3808","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v3\/product"}],"about":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/media\/3810"}],"wp:attachment":[{"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/media?parent=3808"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=3808"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wdeerelec.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=3808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}